EAPSP n×1×1.4

Application

The cables are used as railway cables and can be installed directly into the ground or in ducts.

Standard

  • RENFE E.T. 03.365.051.6

Cable Construction

EAPSP-n×1
  • Conductors: Soft annealed solid copper, 1.4 mm nominal diameter.
  • Insulation: PE insulation.
  • Stranding: Cores are helically stranded in concentric layers.
  • Core Wrapping: Plastic tape(s) with overlapping.
  • Moisture Barrier: One laminated sheath made of aluminium tape (0.2mm thick) coated with copolymer on at least one side is applied longitudinally with overlap.
  • Inner Sheath: PE sheath.
  • Armour: One corrugated steel tape is longitudinally applied with overlap.
  • Outer Sheath: PE sheath.

Electrical Characteristics at 20℃

Nominal Conductor Diameter mm 1.4
Maximum Conductor Resistance Ω/km 11.7
Minimum Insulation Resistance @500 V DC MΩ.km 25000
Resistance Unbalance % 2
Test Voltage @50Hz 1min
Core to Core Veff 2100
Core to Screen Veff 2500
Core to Armouring Veff 2000

Mechanical and Thermal Properties

  • Minimum Bending Radius: 10×OD
  • Temperature Range: -30℃ to +70℃ (during operation); -10℃ +50℃ (during installation)

Dimensions and Weight

Cable Code Number of
Cores
Nominal Sheath Thickness
mm
Maximum Overall
Diameter
mm
Nominal
Weight
kg/km
Inner Outer
1.4mm Conductor, 2.6mm Insulated Wire
RS/EAPSP-2Y(L)2Y(SR)2Y-4C1.4 4 1.3 1.4 15.7 270
RS/EAPSP-2Y(L)2Y(SR)2Y-7C1.4 7 1.3 1.4 17.1 350
RS/EAPSP-2Y(L)2Y(SR)2Y-9C1.4 9 1.3 1.4 19.9 420
RS/EAPSP-2Y(L)2Y(SR)2Y-12C1.4 12 1.3 1.4 20.0 480
RS/EAPSP-2Y(L)2Y(SR)2Y-19C1.4 19 1.3 1.4 22.0 630
RS/EAPSP-2Y(L)2Y(SR)2Y-27C1.4 27 1.3 1.4 24.8 810
RS/EAPSP-2Y(L)2Y(SR)2Y-37C1.4 37 1.3 1.4 26.9 1010
RS/EAPSP-2Y(L)2Y(SR)2Y-48C1.4 48 1.3 1.4 29.7 1240
RS/EAPSP-2Y(L)2Y(SR)2Y-61C1.4 61 1.3 1.4 31.8 1490